Titanium Anode for Swimming Pool

Original
brand: MTCO-M
price: Negotiable
minimum:
Total supply:
Delivery term: The date of payment from buyers deliver within days
seat: Shaanxi
Validity to: Long-term effective
Last update: 2020-04-07 09:57
Browse the number: 162
inquiry
Company Profile
 
 
Product details

Titanium Anode For Swimming Pool

Product description:

Basic materials

Coating oxide

Titanium materials, Gr1,Gr2

Ruthenium oxide, iridium oxide and titanium oxide.

Product appearance and specifications:

Plate, rod, sheet, wire, mesh, tube, ring, belt, net basket and other specifications and any other shapes and sizes (can be designed according to user needs).

Application field:

Precious metal plating;

Surface electroless copper, nickel, zinc, tin;

Printed circuit board system;

Hospital sewage treatment.

Precautions for use:

1. Prevent the surface active catalyst from being scratched or scratched by hard objects during installation and use;

2. Take it out of the electrolytic cell when it is stopped for a long time, rinse the surface with clean water, and store it dry;

3. The higher the current, the stronger the acidity of the electrolyte, the frequent use of power off, the shorter the life;

4. Use in solutions containing fluoride ion, acetonitrile, acetonitrile methane, phenolsulfonic acid, thiourea, etc., will quickly damage the electrode.

Examples:

Production of sodium chlorate by electrolytic salt water;

1. Current density: 2000 ~ 2500A / M2;

2. Sodium chloride concentration: 250 ~ 350g / l;

3. Temperature: 40 ~ 50 ° C;

4. Service life: 6 Years.

Titanium-based metal oxide anodes are used for dilute brine electrolysis sodium hypochlorite anodes, seawater electrolysis sodium hypochlorite anodes, tap water sterilization, sewage treatment series electrode products, seawater desalination electrodes, and elimination of plankton in industrial circulating water. Our company researches and designs according to the specific working conditions of low-concentration brine electrodes, and fully takes into account the temperature fluctuation fluctuation of seawater electrolysis.

http://www.metal-ti.com/